fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni/the-assessment-of-renewable-energy-projects-for-community-benefit-in-west-harris.pdf
3: NPV vs investment cost for loch with 1 meter height............................................ 32 Figure 7.6.4: NPV vs investment cost for loch with 2 meters height ................................. [...] at a height of 157meters with an area of 59000 m2. This loch is the biggest storage option available for this site of Gleann Dub- hlinn. It is located at a distance of around 850 meters from the intake. [...] generated with 2.5 meters dam height. We can establish from the same figure that the most significant amount of additional energy can be achieved with an increase of height from 0 to 0.5 meters. Height of dam
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/options-for-development-of-community-wind-energy-projects-in-the-north-isles-of-shetland-2007-.pdf
kilowatt hour ms-1 Meter per second MW Megawatt MWh Megawatt hour p/kWh Pence per kilowatt hour ₤/kwh pound per kilowatt ₤/y pound per year m³ Cubic meter Nm³ Normalized cubic meter Km Kilometer Optio [...] energy meters are designed to read at 50Hz frequency and do not read the generation when the frequency goes beyond 50 Hz. However Proven Energy Ltd is in the process of manufacturing new energy meters which [...] example Enercon E-33) . The rotor diameter of the turbine is 33.4 meter. So the distance between the turbine and any buildings has to be 334 meter. The turbine could generate a maximum of 1,530 MWh per year
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-ecological-footprint-of-the-sleat-peninsula-2008-.pdf
Nature UK : United Kingdom LIST OF UNITS t : tonnes Ecological Footprint of Sleat XII m2 : Square meter MJ : Mega Joule l : Litre gha : Global hectare ha : Hectare KJ : Kilo Joule Km : Kilometer KWh : Kilowatt [...] 2004 in GEMIS 4.2 Ecological Footprint of Sleat 17 Data Sources Since water consumption is not metered, information on the total water consumption was collected from Scottish Water. The data on energy
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/sesam-african-workshop-2008-final.pdf
relative humidity for the last 3 decades and that the shoreline had been receding at approximately 2 meters annually. In his study he put forward specific recommendations such as the passing of a new legislation
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/integrating-renewable-energy-technology-for-heat-demand-and-a-hydrogen-economy-for-unst-ic-2019.pdf
Friction Loss per 100ft (psi) Pressure Loss per meter of pipe (pas/m) Actual Pipe Length (m) Fittings Resistance 33% Effective Pipe Length/ m Branch Head Loss (Meters Head) Main Saxa Vord Pipe from Storage to [...] Renewable Energy Agency kg kilogram kJ kilojoules kWh kilowatt hour xix LHV Lower heating value m3 cubic meter MCS Microgeneration Certificate Scheme MJ megajoules MOD Ministry of Defence MSDS Material Safety [...] (Jones et al., no date, p. 36) and fittings resistance of 33 %. Furthermore, the pressure loss per meter of pipe was based on D'Arcy-Weisbach Equation friction loss chart (Steel and Friction, no date). The
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/a-leap-towards-energy-sustainability-for-loope-head-communities-2020.pdf
should not be within 200 meters from residential areas and 10 meters from public roads, were ensured by constructing 200 meters buffers around Kilkee and Carrigaholt and 10 meters buffer around the roads [...] District heating piping calculations were based on 400 Euro per meter for a pipe capacity of 0.5 MW (ETSAP, 2013 ); gas piping cost of 93 Euro per meter (Brian H. Jacobsen F. M., 2013); and transport cost of 0 [...] simulated with a hub height of 59 meter, like the existing wind turbines in the farm in Loop Head. Since, the wind turbine in existing wind farm in Loop Head is at 59 meter hub height, it is important to
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
– University of Flensburg, Germany 59 is approximately 2 meters at the center and 1 meter at the edge. It is about 800 meters long and 140 meters wide. Figure 5.8: Proposed lay out of Govig Micro Hydro [...] Kilo Volt ampere kW = Kilowatt kWh = kilo watt hour l/s = liter per second m = meter m3 = cubic meter m3/s = cubic meter per second MW = Megawatt MWh = Megawatt-hour odt = oven dry ton List of Currencies [...] 4500 meters (Considering 30 meters loop length each and 0.3m apart from each other and 3 loops in one line) Heat recovery from discharge water 180 KW (Considering 1KW power recovery from 25 meter loop
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/znes-discussionpapers-009-100ee-praslin-ladigue.pdf
(250,000 kWh) is about 317 500 m3. At an average water depth of 20 meters each storage lake would measure approximately 126 by 126 meters. As Praslin has substantial suitable areas with an elevation around
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/znes-discussionpapers-008-100ee-mahe.pdf
000,000 kWh) is about 625,000 m3. At an average water depth of 20 meters each storage lake would measure approximately 175 by 175 meters. As Mahé has substantial areas with an elevation around 600 m above
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/diskussionsbeitraege-002.pdf
und Wäschetrockner wurde nicht separat eingegangen, sondern die Thematik „Smart-Metering“ diskutiert. Beim Smart- Metering handelt es sich nicht um eine Technologie die den Stromverbrauch reduziert, Anhang [...] werden durch die Bohrungen bestimmt. Je gebohrtem Meter werden Kosten von ca. 1.000 € verursacht. In Flensburg müsste je Richtung mindestens 3.500 Meter tief gebohrt werden. Insgesamt bedürfte es einer [...] Energieberatung noch kleinteiliger als auf Stadtteilebene durchführen (Nähe zur Bevölkerung!) • Smart Metering/ Smart Devices/ Wärmemengenzähler einsetzen • Gesamtkonzept entwickeln: Wärme, Strom, Lüftung •