fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/towards-sustainable-energy-a-roadmap-for-residential-buildings-at-loop-head-ic-2022.pdf
1.41 W/m2 ∙K Roof (100 mm mineral wool insulation) 0.22 W/m2 ∙K Ground floor (uninsulated, solid) 0.84 W/m2 ∙K Mezzanine floor (uninsulated, solid) 0.28 W/m2 ∙K Windows (double-glazed) 2.2 W/m2 ∙K External [...] 27 W/m2 ∙K First floor Pitched roof: insulated on rafter 0.49d W/m2 ∙K Second floor Pitched roof: insulated on rafter 0.25d W/m2 ∙K Ground floor (solid) 0.34d W/m2 ∙K Second floor (solid) 0.37d W/m2 ∙K [...] 1.64d W/m2 ∙K Roof (No insulation) 2.3d W/m2 ∙K Ground floor (uninsulated, solid) 0.61d W/m2 ∙K Windows (Single glazed metal frame) 5.7d W/m2 ∙K Windows (Single glazed wood/pvc frame) 4.8d W/m2 ∙K External
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
14 16 0% 10% 20% 30% 40% 50% C u m u la ti ve c o st , m ill io n E u ro Heat Savings University of Flensburg Energy & Environmental Management in Developing Countries (M. Eng.) International Class 24 4 [...] Pre-refurbishment Parameters of the Selected House Material Current U- value, W/m2 Surface Area, m2 Current heat losses, kWh/m² Wall Solid stone 2.1 80 168 Roof Pitched, insulation between joists 0.68 100 [...] Area requirement 40 m2/kWp Roof -Top Solar System Area Requirement 10 m2/kWp Optimal Tilt Angle 390 University of Flensburg Energy & Environmental Management in Developing Countries (M. Eng.) International
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/present-situation-sustainable-energy-scenario-of-lochboisdale-up-to-2014-2009-.pdf
tonnes/y Natural Gas Manufacturing Heating Cooking Others (……………………………………) …………..m3/y …………..m3/y …………..m3/y …………..m3/y …………..m3/y Electricity Manufacturing Lighting Heating Cooking Office equipment/Entertainment [...] 11 in Lochboisdale is found to be 157 kWh/m2. But benchmark heating index in Scotland is 91 kWh/m2 which consists of 58 kWh/m2 for space heating and 33 kWh/m2 for water heating13. This shows that the average [...] site has a spring tidal range up to 3.6 m. This report has also mentioned the design of a mean basin area of 1.92 km2, dam length below 130 m and above low water 450 m. This site will be producing electricity
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/options-for-development-of-community-wind-energy-projects-in-the-north-isles-of-shetland-2007-.pdf
of 82 m above MSL (mean sea level) for the duration of January, 1930 to December, 2002. Figure 2.2. Long term mean wind speed from January 1930 to December 2003 0 20 40 60 80 100 JAN FEB M AR APR M AY JUN [...] Wind turbine (5 x 15 kW) 75 kW 2,666 13,000 2. Storage tank 12 m3 430 335 3. Cost of pipeline including (valves, bends etc.) 700 m 270 12,285 4. Heat exchanger 1 set 42,400 5. Pump 1 10,000 650 Annual Revenue [...] exchanger for 7 commercial (heat exchanger @5000 ₤/HH) - 45,000 - ₤ cost for hot water storage ( 550 m3 @ 430₤/m3 ) - 236,500 - ₤ control system (estimation) - 500,000 - ₤ TOTAL Investment 2,215,444 3,416,944
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/forschungsergebnisse/klimaschutzkonzept-nordkirche.pdf
Mobilität M Pol 1 Reisekostengesetz M Pol 2 CO₂-Höchstgrenze Dienstwagen M M&C 1 Arbeitswegebefragung M M&C 2 Reisekostenabrechnung M 1.0 Mobilitätsmanagement M 1.1 Radverkehr M 1.2 Telearbeit M 2.1 Halbierung [...] Baualters- klasse Anteil am EV spez. EV 2010 Bis 2016 Bis 2021 Bis 2031 Bis 2050 [kWh/m²a] [kWh/m²a] [kWh/m²a] [kWh/m²a] [kWh/m²a] - bis 1949 70% 141,2 120,0 90,0 80,0 70,0 - bis 1968 23% 141,2 120,0 90,0 80 [...] Alters- klasse Anteil am EV spez. EV 2010 Bis 2016 Bis 2021 Bis 2031 Bis 2050 [kWh/m²a] [kWh/m²a] [kWh/m²a] [kWh/m²a] [kWh/m²a] - bis 1949 17% 140,7 90,0 80,0 70,0 60,0 - bis 1968 32% 140,7 90,0 80,0 70,0
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/diskussionsbeitraege/diskussionsbeitraege-002.pdf
000 40 kWh/m²a 60 kWh/m²a 80 kWh/m²a 100 kWh/m²a 120 kWh/m²a 140 kWh/m²a 160 kWh/m²a 180 kWh/m²a Ja h re sv e rb ra u ch 2 0 1 0 in M W h Spezifischer Heizenergieverbrauch im Jahr 2010 in kwh/m² Nettogrundfläche [...] 3000 40 kWh/m²a 60 kWh/m²a 80 kWh/m²a 100 kWh/m²a 120 kWh/m²a 140 kWh/m²a 160 kWh/m²a 180 kWh/m²a Ja h re sv e rb ra u ch 2 0 2 0 in M W h Spezifischer Heizenergieverbrauch im Jahr 2020 in kwh/m² Nettogrundfläche [...] 3000 40 kWh/m²a 60 kWh/m²a 80 kWh/m²a 100 kWh/m²a 120 kWh/m²a 140 kWh/m²a 160 kWh/m²a 180 kWh/m²a Ja h re sv e rb ra u ch 2 0 3 0 in M W h Spezifischer Heizenergieverbrauch im Jahr 2030 in kwh/m² Nettogrundfläche
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/seminare/soziologie/dokumente/culture-practice-and-europeanization/cpe-vol.5-no.1-2020/cpe-5-1-pp1-15-lueg-carlson-2020.pdf
57(2), 297-329. Hyvärinen, M., Hydén, L.-C., Saarenheimo, M., & Tamboukou, M. (2010). Beyond narra- tive coherence: an introduction. In M. Hyvärinen, L.-C. Hydén, M. Saarenheimo, & M. Tamboukou (Eds.), Beyond [...] Studies, 29(5), 885- 899. Bal, M. (1997). Narratology: introduction to the theory of narrative (2. ed.). Toronto: Uni- versity of Toronto Press. Bamberg, M., & Andrews, M. (2004). Considering counter-n [...] Andrén, M., Lindkvist, T., Söhrman, I., & Vajta, K. (Eds.) (2017). Cultural borders of Eu- rope. Narratives, concepts and practices in the present and the past. New York: Berghahn. Antonsich, M. (2008)
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/forschungsergebnisse/20190426endbericht-openego-fkz0325881-final.pdf
Verteilung von Erzeugern rea/ego_dp_rea_m1.sql M1 Biomasse- und Solaranlage verteilt nach OSM Agrarflächen rea/ego_dp_rea_m2.sql M2 Windparks rea/ego_dp_rea_m3.sql M3 Windanlagen zu Windpotentialflächen WPA [...] kleinen Erzeugungsanlagen rea/ego_dp_lattice_500m.sql Erstelle Rastergitter (Punktnetz) 500m rea/ego_dp_lattice_50m.sql Erstelle Rastergitter (Punktnetz) 50m rea/ego_dp_rea_- wpa_per_mvgd.sql Windpotentialflächen [...] chen (WPA) rea/ego_dp_rea_- lattice_per_area_500m.sql Vorbereitung des 500m Rastergitters rea/ego_dp_rea_- lattice_per_area_50m.sql Vorbereitung des 50m Rastergitters rea/ego_dp_rea_setup.sql Setup von
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
period of one year has been shown. The most prevalent wind speeds are between 6-8 m/s at 25m height and 7-9 m/s at 50m height. This means that the most commonly occurring wind speed is quite high in Durness [...] 2012) Usually schemes are categorized according to the head: low head: H < 30 m medium head: 30m < H < 100m high head: H > 100 m 61 6.3 Resource Assessment 6.3.1 Hydro project development methodology The [...] Balnakeil Central Durness Land Area (m2) 41097 221994 Area of Houses (m2) 6600 10538 Pipeline length (m) 690 1295 Heating Demand (kWh) 290731 875570 Heat Density (kWh/m2) 7.07 3.95 Table 29. Heat density
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/industrial/dokumente/downloads/veroeffentlichungen/forschungsergebnisse/konzept-masterplan-100-klimaschutz-fuer-flensburg.pdf
EnEV 30 kWh/(m² a) 10 kWh/(m² a) 10 kWh/(m² a) Kennwerte Neu- bau gemäß KSK Vgl. Hohmeyer et al., 2011 Gemäß EnEV 2012 65 kWh/(m² a) Gemäß EnEV 2012 65 kWh/(m² a) Gemäß EnEV 2012 65 kWh/(m² a) Gemäß EnEV [...] EnEV 2012 65 kWh/(m² a) Ziel-Kennwert bei Komplettsanierung Gemäß EnEV (70-80 60 kWh/(m² a) 50 kWh/(m² a) 40 kWh/(m² a) Kommunale Liegenschaften 241 Universität Flensburg MASTERPLAN 100 % KLIMASCHUTZ FLENSBURG [...] FLENSBURG kWh/(m² a)) Kennwerte Kom- plettsanierung gemäß KSK 70-80 kWh/(m² a) 60-70 kWh/(m² a) 70 kWh/(m² a) Keine Komplett- sanierung in die- sem Zeitraum Die zugrunde gelegten ambitionierteren energetischen
-
File type
- application/pdf
-
Referenced at
-