/en/international/languages/language-center/questions
Frequently asked questions Listen Registration Who can participate in the language courses? Only EUF students and staff are allowed to take part in the language courses. When can I register for the la
/en/international/coming-to-flensburg/international-students/application-and-courses/exchange-students/courses-fall-semester
Course offer for exchange students and virtual courses for all students - Fall Semester Listen The university follows the open door policy , which means students can take courses of different study pr
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/1.-eem-international-class-2015-achiltibuie-final.pdf
100 125 150 175 200 225 250 0 2 4 6 8 10 12 14 16 18 20 22 24 P o w e r O u tp u t (k W ) Wind speed[m/s] Power Curve [kW] Power Output [kW] 0.00 50.00 100.00 150.00 200.00 250.00 1 1001 2001 3001 4001 [...] heaters 8 8,7% electric panel heater 13 14,1% heat pump 4 4,3% gas 9 9,8% oil 25 27,2% solid fuel 23 25,0% Not known 10 10,9% TOTAL 92 [24] Electrical heating systems amount to 25, including the heat pumps [...] 8 0 7 5 3 1 7 7 8 2 8 0 3 3 8 2 8 4 8 5 3 5 H ea t d em an d ( kW ) Tíme (hourly) 0 50 100 150 200 250 1 2 9 3 5 8 5 8 7 7 1 1 6 9 1 4 6 1 1 7 5 3 2 0 4 5 2 3 3 7 2 6 2 9 2 9 2 1 3 2 1 3 3 5 0 5 3 7 9 7
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2014-applecross-report.pdf
? (the recommended is 270mm) ___ 12 mm (1/2”)1 ___ 25 mm (1”)2 ___50 mm (2”)3 ___ 75 mm (3”)4 ___ 100 mm (4”)5 ____ 150 mm (6”)6 ____ 200 mm (8”)7 ___ 250 mm (10”)8 ___ 300 mm + (12”+)9 ___ Don’t know [...] Double glazing? 4% 2% 8% 0% 20% 14% 14% 10% 22% 6% 0% 5% 10% 15% 20% 25% 12 mm 25 mm 50 mm 75 mm 100 mm 150 mm 200 mm 250 mm 300 mm Other Depth of insulation 26% 23% 26% 25% 2% 0% 5% 10% 15% 20% 25% 30% Cavity [...] Wall Structures 250 mm of stones 6” of timber framed 600 mm of stones (old walls) 100 mm of cavity 100 mm Rockwool 25 mm of joist (old walls) 12,5 mm of plaster board 50 mm cavity 20 mm of concrete (new
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
dimensions Weight kW H mm D mm W mm empty kg PYROT 100 80 – 100 1765 2194 1050 1895 PYROT 150 120 – 150 1765 2444 1050 2200 PYROT 220 180 – 220 2024 2444 1330 3080 PYROT 300 250 – 300 2024 2816 1330 3560 [...] Nominal output Burner dimensions Weight kW H mm D mm W mm empty kg Pyrtec 140 100 - 150 1640 1693 950 2135 Pyrtec 200 150 - 220 1640 2139 950 2755 Pyrtec 350 250 - 360 1980 2389 1110 4175 Pyrtec 500 380 - [...] roof insulation. The roof insulation thickness varies from 25 mm to 120 mm. The houses with no insulated roof, can insulate their loft 200 mm which is recommended also by Communities Scotland (Fuel poverty
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/community-development-projects-for-the-supply-of-heat-and-electricity-from-renewables-in-the-isles-of-barra-and-vatersay-2009-.pdf
beside figure (in meter). - Estimated Price: 80 Euro/m 3 - Materials: o 2,5 mm HDPE liner. o Iron grid (150 x 150 mm, ø 8 mm) o 75 mm mineral wool. o Insulation. o Aluminium cover. Figure 35. On-ground storage [...] kilowatt-hour ltrs litres xv m metre m/s meters per second m 2 square metre m 3 cubic metre MJ mega joule mm millimetre MWh megawatt-hour p pence (British) t tonne yr year xvi 1. Introduction 1.1. Purpose and [...] 2006 p. 67 10 The Scottish Government estimates the average heating index for Scottish households as 250kWh/m 2 /yr 4 . In the SEEM report 5 , the annual heating demand for households in the area was found
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/the-transport-sector-in-rousay-and-eday-energy-cost-and-emissions-compared-to-kirkwall-2010-.pdf
45 mm 45 mm 0.20 m³ 0.10 T Wood 800 m 25 mm 50 mm 1 m³ 0.5 T Wood 340 m 10 mm 38 mm 0.13 m³ 0.065 T Wood 54 m 21 mm 195 mm 0.22 m³ 0.11 T Wood 90 m 21 mm 95 mm 0.18 m³ 0.09 T Wood 90 m 12 mm 70 mm 0.08 [...] (Roof) 2,706 tiles 418 mm 334 mm mm 0 m³ 13.81 T Wood 672 m 45 mm 195 mm 5.90 m³ 2.95 T Wood 144 m 45 mm 145 mm 0.94 m³ 0.47 T Wood 884 m 45 mm 95 mm 3.78 m³ 1.89 T Wood 408 m 45 mm 70 mm 1.29 m³ 0.64 T Wood [...] 2,440 mm 1,220 mm 12 mm 0.50 m³ 0.40 T Plywood 10 boards 2,440 mm 1,220 mm 9 mm 0.27 m³ 0.21 T Laminate (woodchip) 2 boards 2,440 mm 1,220 mm 18 mm 0.18 m³ 0.09 T Gypsum 8 boards 2,400 mm 1,200 mm 12.5
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-of-renewable-energy-technologies-for-the-sustainable-development-of-the-isle-of-jura-2012-.pdf
Estate d=400mm 1,280 16,250 12.70 31.25 30.4 48.04 7.8 Ardlussa 1,540 11,250 7.31 31 Assumed Corran river cost d=250mm 3,600 45,703.13 12.7 31.25 30.4 14.04 7.8 Assumed Corran river cost d=350mm 35.29 Assumed [...] layout The optimum Penstock sizes for 50 kW, 100 kW and 330 kW capacities are calculated as 250 mm, 350 mm and 500 mm respectively. High Density Polyethylene (HDPE) pipe material is suggested as it is durable [...] £158,224 £261,169 Export income (£/year) £7,654 £22,343 £24,578 £40,570 O &M cost (£/year) £1,250 £ 3x1,250 £12,600 £20,000 Loan and interest payments (year 1-15) (£/year) £49,259 £104,350 £74,890 £109
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-and-future-scenarios-of-knoydarts-electricity-system-2013-.pdf
an enlarger of 300 mm then changing to a plastic pipe of external diameter 315 mm. Penstock The penstock has sections of steel and plastic pipes of internal diameters 258 mm and 295 mm respectively (Knoydart [...] Gross Head 145 m Head Loss 3.395m Net Head 141.60 m Penstock Length 1022m Penstock Diameter 300 mm and 250 mm Installed capacity (full capacity available for 37% of the year) 65.00 kW Power House NG 174880 [...] registered in an excel sheet to acquire the shape of land as shown in Figure 38. The pipe of 300mm, 250mm and 225mm diameters are selected for the penstock using a nomogram. Figure 37: One Example of River Scottas
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
Trust Hydro with a rated capacity of 89kW had investment -200 -150 -100 -50 - 50 100 150 200 250 100 150 200 250 300 350 N P V ( 1 ,0 0 0 £ ) Investment costs (1,000 £) NPV vs Investment cost at 2.5% inflation [...] 12.41 14.02 14.43 16.53 Hydro 65 kw Investment costs (£) 100,000 150,000 200,000 219,000 250,000 300,000 306,250 350,000 IRR 22.7% 15.3% 11.1% 10.0% 8.3% 6.2% 6.0% 4.6% NPV (£) 201,967 154,322 106,539 88 [...] 28 below: Local 11kV 3-Phase Grid Capacity Estimate Voltage Size 11kV Conductor Type and Size Cu 25mm2 Current carrying capacity 133 A Power factor 0.9 Maximum Capacity (90% loading) 2053kW Table 28. Grid