fileadmin/content/institute/anglistik/dokumente/projekte/dohcce-online.pdf
show me /wels/. Come here. [S. zeigt Wales]. 37 Mm. [zustimmend] Now! 38 S. I can see Liverpool. 39 L. Yes. Now, show Liverpool. 40 [S. zeigt Liverpool] 41 Mm. [zustimmend] 42 S. I can see … 43 [S. zeigt [...] 2952 S. A chair is in the picture. 2953 L. Mm, Helmut. 2954 S. A cat is in the picture. 2955 L. Eh, [äh], Robin. 2956 S. A game is in the picture. 2957 L. Mm and Peggy. 2958 S. A bis…cuit is in the picture [...] sweets. 277 L. Come here. 278 [S. agiert] 279 L. Betty? … Betty? … [Gelächter] Betty? … Look here, 280 please. … Petra. 281 S. Betty doesn’t want /ʃwi:ts/. 282 L. Yes. … Betty? … Christiane. 283 S. Betty
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/alumni/yb-2014-eem-ppre.pdf
components Description of Material Numbers Creosote Wooden Poles 126 Conductor (AAC 25mm 2 ) 4 times 2,280m Conductor (AAC 53mm 2 ) 4 times 1,440m LT Hook N-95 & LT Insulator N-95 375 each Galvanized wire 10 [...] current build-up of 120.42 A at the last node. In that case, an AAC with cross-sectional area of 53.51 mm 2 was selected. The conductor has a current rating of 248 A (Product catalogue, 2012) that fits the [...] (Inversin, 2000). Since the voltage drops in the other sections are relatively lower, an AAC with 21.15 mm 2 was found appropriate and economical for those sections as found in Table 6. Table 5 summarizes the
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/2017-final-report-international-class.pdf
(£) (55,000 for grid connection) 22,000 22,000 22,000 22,000 Installation costs (£) 32,032 41,888 49,280 24,640 Project management (£) 24,640 24,640 24,640 24,640 Land purchase (£) 21,560 21,560 21,560 21 [...] 28 below: Local 11kV 3-Phase Grid Capacity Estimate Voltage Size 11kV Conductor Type and Size Cu 25mm2 Current carrying capacity 133 A Power factor 0.9 Maximum Capacity (90% loading) 2053kW Table 28. Grid [...] Central Durness Gas Boiler £9,581.00 £ 14,371.50 Electric Boiler £11,304.35 £ 27,685.00 Storage £20,280.00 £ 96,000.00 Pipe Line cost £176,000.00 £ 277,586.00 House Interface (DH) £55,000.00 £ 110,000.00
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/integrating-renewable-energy-technology-for-heat-demand-and-a-hydrogen-economy-for-unst-ic-2019.pdf
015 kJ/kgK Density 570 kg/m^3 Thickness 100 mm 3 Polystyrene' Ext-Walls 92 Conductivity 0.14 kJ/hmK Capacity 1.25 kJ/kgK Density 30 kg/m^3 Thickness 100 mm 3 Polystyrene Floor 92 Conductivity 0.14 kJ/hmK [...] Capacity 1.25 kJ/kgK Density 30 kg/m^3 Thickness 3 mm 4 Cork Floor 92 Conductivity 0.16 kJ/hmK Capacity 0.18 kJ/kgK Density 100 kg/m^3 Thickness 4 mm . 70 6.5.2 Building Energy Efficiency Study Scenarios [...] - 2. Mineral wool Thickness 100 mm Ext-Walls 52.51 180 £/m2 25 9451.80 conductivit y 0.1 3 kJ/hmK capacity 0.9 kJ/kgK - - - - density 80 kg/m^3 - - - - Thickness 100 mm Roof 123.5 8 40 £/m2 4943.2 Total
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/1.-eem-international-class-2015-achiltibuie-final.pdf
- 1 (peak demand 80kW) £9,850 - £2.5 / kW Achiltibuie Primary School - - 1 (peak demand 49 kW) £4,280 £9,000 (Assumed: 2 Semi-Detached) £2.5 / kW Total DHN Investment £253,372 Operation Pumping Cost ( [...] to take into consideration the remaining capacity of the network that is assumed to be 600kW. The 32mm2 copper conductor as indicated in the SSE grid map has rated current for different seasons at 50°C [...] the conductor specifications for the 33 kV line are 3-phase CAD copper wire with a size equal to 60 mm2, according to the SSE grid map. The rated currents for this conductor for the different seasons were
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/a-sustainable-energy-model-for-a-circular-economy-a-case-study-of-creed-integrated-waste-management-facility-stornoway-western-isles.pdf
Water The cost of potable water depends on the meter size and volume used. The cost of water for 25mm and 100mm is Pound 0.7068 per m3 for the first 100,000 m3 used. This figure was used to calculate the total [...] estimate the mortalities of Lewis and Harris. 100.0 120.0 140.0 160.0 180.0 200.0 220.0 240.0 260.0 280.0 2005 2010 2015 2020 2025 2030 Sa lm o n P ro d u ct io n ( To n n es ) Th o u sa n d s Year Scotland's [...] Scotland Directorate, 2018) Month Lewis Lewis & Harris Jan 102.9 153.1 Feb 104.3 155.1 Mar 64.1 95.4 Apr 28.0 41.7 May 35.0 52.1 Jun 67.5 100.5 Jul 108.4 161.3 Aug 129.3 192.4 Sep 118.9 176.9 Oct 96.3 143.3 Nov
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/assessment-and-future-scenarios-of-knoydarts-electricity-system-2013-.pdf
an enlarger of 300 mm then changing to a plastic pipe of external diameter 315 mm. Penstock The penstock has sections of steel and plastic pipes of internal diameters 258 mm and 295 mm respectively (Knoydart [...] registered in an excel sheet to acquire the shape of land as shown in Figure 38. The pipe of 300mm, 250mm and 225mm diameters are selected for the penstock using a nomogram. Figure 37: One Example of River Scottas [...] Head Loss Project Site Powe r (kW) Head (m) Discharg e (m3/s) K 5% HL(m) Length(m) ∆H (m/m) Nomo Dia(mm) Selected Dia(mm) HL= (410/3*Q2L)/(π2k 2D16/3 V ) ξ = Q/A ξ*V2 Total H/2g Difference L Remark Net head
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/exploring-sustainable-energy-options-for-loop-head-ic-2021.pdf
that the roof would be insulated by an additional layer of 200 mm mineral wool, while walls would be insulated by applying approximately 120 mm of external insulation which brings the U-value of roof and [...] hourly demand (kW) 0 0.385 0.435 0.460 0.522 0.404 0.438 0.379 0.416 1 0.280 0.329 0.329 0.385 0.292 0.345 0.273 0.317 2 0.242 0.267 0.280 0.311 0.255 0.283 0.242 0.261 3 0.230 0.242 0.261 0.273 0.236 0.249 [...] 224 0.236 5 0.236 0.236 0.267 0.264 0.236 0.245 0.230 0.236 6 0.292 0.261 0.342 0.298 0.298 0.261 0.280 0.252 7 0.479 0.342 0.565 0.401 0.479 0.354 0.447 0.339 8 0.615 0.479 0.777 0.556 0.603 0.491 0.541
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/potential-of-renewable-energy-in-the-north-harris-trust-area-2005-.pdf
roof insulation. The roof insulation thickness varies from 25 mm to 120 mm. The houses with no insulated roof, can insulate their loft 200 mm which is recommended also by Communities Scotland (Fuel poverty [...] excess of 92%”1 The KOB PYROT Model Type of Burner Nominal Output Burner dimensions Weight kW H mm D mm W mm empty kg PYROT 100 80 – 100 1765 2194 1050 1895 PYROT 150 120 – 150 1765 2444 1050 2200 PYROT [...] heating systems1.” Pyrtec size range. Type of burner Nominal output Burner dimensions Weight kW H mm D mm W mm empty kg Pyrtec 140 100 - 150 1640 1693 950 2135 Pyrtec 200 150 - 220 1640 2139 950 2755 Pyrtec
-
File type
- application/pdf
-
Referenced at
-
fileadmin/content/abteilungen/developing-countries/dokumente/downloads/international-class/ic-2014-applecross-report.pdf
? (the recommended is 270mm) ___ 12 mm (1/2”)1 ___ 25 mm (1”)2 ___50 mm (2”)3 ___ 75 mm (3”)4 ___ 100 mm (4”)5 ____ 150 mm (6”)6 ____ 200 mm (8”)7 ___ 250 mm (10”)8 ___ 300 mm + (12”+)9 ___ Don’t know [...] Double glazing? 4% 2% 8% 0% 20% 14% 14% 10% 22% 6% 0% 5% 10% 15% 20% 25% 12 mm 25 mm 50 mm 75 mm 100 mm 150 mm 200 mm 250 mm 300 mm Other Depth of insulation 26% 23% 26% 25% 2% 0% 5% 10% 15% 20% 25% 30% Cavity [...] Wall Structures 250 mm of stones 6” of timber framed 600 mm of stones (old walls) 100 mm of cavity 100 mm Rockwool 25 mm of joist (old walls) 12,5 mm of plaster board 50 mm cavity 20 mm of concrete (new walls)
-